18 User Manual SATEL
Remove user – allows to remove the existing users (see: section REMOVE USER p. 27).
The administrator defines whether the installer is to have access to the USERS
submenu (SERV. CAN EDIT option in the CHANGE OPTIONS submenu).
Masters – the submenu provides the following functions available to the installer:
New master – allows to create a new administrator.
Edit master – allows to edit the existing administrators.
Remove master – allows to remove the existing administrators.
Zone bypasses – the following functions are available in the submenu:
Inhibit – allows to temporarily bypass the zones (see: section ZONE BYPASSING (INHIBIT)
p. 30).
Isolate – allows to permanently bypass the zones (see: section PERMANENT BYPASSING
(ISOLATE) p. 30).
If the GRADE 3 option has been enabled by the installer, the ISOLATE function is only
available to the installer.
Set time – allows to program the control panel clock. The data are entered in the following
format:
time – hour:minute:second,
date – day:month:year.
System state – allows to view the troubles and, if the GRADE 3 global option has been
enabled by the installer, also the alarms and bypassed zones, as well as to check the
partition status.
Events – the submenu contains functions which allow to view the events saved to the control
panel memory (see: section EVENT LOG REVIEWING p. 31).
Reset zones – running the function will result in a temporary deactivation of the
43. RESETABLE POWER SUPPLY type outputs, thus making it possible to reset the alarm
memory for detectors supplied from those outputs (e.g. fire detectors).
Clear latched outputs – allows to turn off some of the control panel outputs for which the
LATCH option is enabled, as well as the 9. DAY ALARM, 12. SILENT ALARM
and 116. I
NTERNAL SIREN type outputs.
Fin.f.door open – restores the normal operating mode in all modules executing the access
control functions (in case of fire, the doors controlled by these modules may be
automatically unlocked).
Change options – the following functions are available in the submenu:
Keypad chime – turns on/off the chime signal in the keypad (signaling violations of
selected zones).
Outputs chime – allows to block the chime signal from selected partitions on the
11. C
HIME type output.
Timers – allows to program parameters of the timers controlling the 120. THERMOSTAT type
outputs, and other timers, the editing of which is permitted by the installer.
Temperatures – allows to edit the temperature thresholds for 120. THERMOSTAT type
outputs.
Partition timers – allows to program the partition timers (see: PROGRAMMING THE
PARTITION TIMER
p. 32).
No expanders tamper alarms – allows to temporarily disable the expansion module
tamper supervision. In case of any problems with the expansion modules, report the fact
to the installer.