SATELLINE-EASy Pro
User Guide v.1.5
59
value have been edited. Toggle-type parameters (typically with ON/OFF choices modifications
have to be confirmed by pressing the ”SELECT”- or ”SET”-button.
This is the display in Data Transfer
Mode.
TX and RX frequencies are set to
468.525.000 MHz.
Compatibility is Satel 3AS.
TX power is 35W.
Channel spacing is 25 kHz.
Reference frequency is 438.000.000
MHz. Serial PORT 1 settings are
19200, N, 8, 1.
Signal strength info is displayed on the
upper left-hand corner:
- RSSI value Y-102 (here -102 dBm)
of the last received message or
- current noise level e.g. n-115
Battery level respectively on the upper
right corner.
Y-102 11.5V
TX 468.52500 MHz
RX 468.52500 MHz
Compatibility
Satel 3AS
TX power: 35W
Spacing:25kHZ
Ref438.00000MHz
COM1:19200N81
TX:35W SETUP
After pressing the ”SET-UP-button the
display will show the main menu, which
is a list of modifiable parameters.
Pressing the ▲▼ buttons the cursor
moves upwards and downwards. When
the cursor > is placed beside the
desired selection, entry into sub-menu
is done by pressing the SELECT-
button.
>Radio frequency
Radio settings
Addressing
Port 1
Port 2
Handshaking
Additional
Tests
Factory setup
LCD-Contrast
EXIT ▲▼ Select
9.3.1 Changing frequency (frequency of the active TX/RX radio channel)
Press ▲ or ▼ until the cursor
> points to “Radio frequency”
–selection and press ”Select”
to move onto the next
submenu.
>Radio frequency
Radio settings
Addressing
Port 1
Port 2
Handshaking
Additional
Tests
Factory setup
Contrast
EXIT ▲▼ Select